E0 / FE5

NHXMH
Câble courant fort, 300/500 V
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete, except for direct embedding in cast, rammed or vibrated concrete.
Also suitable for outdoor applications.
(N)HXM(St)H
Câble courant fort blindé, 300/500 V
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete, except for direct embedding in cast, rammed or vibrated concrete.
Also suitable for outdoor applications.
Permitted operating temperature...
N2XH
Câble de sécurité, monoconducteur, 0.6/1 kV, Euroclasse Cca
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitt...
N2XH
Câble de sécurité, multiconducteur, 0.6/1 kV, Euroclasse Cca
Pour installations fixes dans des locaux secs, humides ou mouillés, en montage apparent ou encastré, dans la maçonnerie ou le béton. Ces câbles sont aussi prévus pour montage à l'air libre.
L'installation directe en terre ou dans l'eau est...
N2XCH
Câble de sécurité, 0.6/1 kV, Euroclasse Cca
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications.
The cable should only be laid directly in earth or water if a protective conduit is used.
Permitte...
J-H(St)H…BD
Câble d'installation pour systèmes de télécommunication, max 300 V, Euroclasse Dca
Installation cable with electrostatic shield for areas vulnerable to fire and with high concentration of people and property value. For ICT systems for lossless data and signal transmission. Suitable for laying in dry and humid rooms,...
J-H(St)H…BD alarme incendie
Câble d'alarme incendie, max 300 V
Installation cable with electrostatic shield for areas vulnerable to fire and with high concentration of people and property value. For ICT systems for lossless data and signal transmission. Suitable for laying in dry and humid rooms,...
FE5-CL
Câble de sécurité, 0,6/1 kV, avec protection contre les rongeurs
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications.
The cable should only be laid directly in earth or water if a protective conduit is used.
Permitte...
FE5-CL
Câble de sécurité, 0,6/1 kV, avec protection contre les rongeurs
Convient pour une installation fixe dans des endroits secs, humides ou mouillés, en montage apparent ou encastré, ainsi que dans la maçonnerie ou le béton. Ces câbles sont également appropriés pour usage en extérieur.
L'installation directe...
FE5-CL
Câble de sécurité, 0,6/1 kV, avec protection contre les rongeurs
Convient pour une installation fixe dans des endroits secs, humides ou mouillés, en montage apparent ou encastré, ainsi que dans la maçonnerie ou le béton. Ces câbles sont également appropriés pour usage en extérieur.
L'installation directe...