FL – Low Fire Hazard – unsupported

Drawing according to article number 191113 - Type 8582-F

Descripción

Elevator suspension cable for indoor and panoramic elevators.
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
Core flexible:class 5
Core insulation:low fire hazard
Data elements:

Please find our detailed interactive product overview here.

Supporting members:none
Outer sheath:low fire hazard
Rated voltage Uo/U:according to table
Free suspension length:maximum 45 m
Travelling height:maximum 80 m
Running speed:maximum 4 m/s
Acceleration:< 0.8 m/s2
Operating temperature:-15 to +70 °C
Recommended loop diameter:according to table, tolerance -50/+100 mm
Core:black, white numbered,
G = with green-yellow core(s)
Pair/quad:various colours or black with white numbers
Coax:black

Color de forro

black

Estándares

EN 50214

Documentos

ENDENLFRCNESIT
Ficha técnica del producto

Versiones

N° de artículoMiembros de apoyoDimensiones totales [mm x mm]Superficie seccional transversal [n x mm2]Dispositivo de suspensiónLazo [mm]Elementos de datosProductoProp. Cu [kg/km]Tensión nominal [V]StandardsPeso [kg/100m]
191110none34.3 x 4.4

12 G 0.75

LZ 10063008511-F87

300/500

EN 5021425.9
185125none49.4 x 4.4

18 G 0.75

LZ 10063008511-F130

300/500

EN 5021438.2
191112none66.7 x 4.4

24 G 0.75

LZ 10093008511-F173

300/500

EN 5021451.1
191111none47.4 x 5.4

12 G 0.75

+ 3 x 2 x 0.50

LZ 1006400

6651-F

8636-F123

300/500

300/300

EN 5021442
182205none72.3 x 5.8

3 G 2.50

+ 14 x 1.00

+ 4 x 2 x 0.34

LZ 1009400

 

 

7345-F

8827-F244

450/750

300/500

300/300

EN 5021473.5
191113none87.3 x 6.5

24 G 1.00

+3 x 2 x 0.75

+ 1 x CX 75 Ω

LZ 1010400

 

6651-F

HF-2123-F

8582-F306

300/500

300/300

EN 5021495.8
190491none47.8 x 7.1

2 x 1.50

+ 8 x 2 x 0.50

+ 1 x CX 75 Ω

LZ 1006450

 

6651-F

HF-2123-F

8582-F149

450/750

300/300

EN 5021452.4