CU 6502 4P / 2x4P F8

Safety cable, 0.6/1kV armoured with rodent protection, Keram

halogen-free, with improved fire characteristics,
with reference to VDE 0266 and CENELEC HD 604 S1,
circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331,
System Circuit Integrity E30-E60* in accordance with DIN 4102-12 

1 Conductor: solid/stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Inner sheath: Polyolefin, flame retardant, low smoke, zero halogen
6 Armouring: galvanised steel tape
7 Sheath: FRNC/LSZH

Descripción

Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of Circuit Integrity E30-E60* in accordance with DIN 4102-12. Circuit Integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor of +90˚C.

ConductorBare copper, solid or stranded, IEC 60228, EN 60228, (VDE 0295)
InsulationDouble insulation, cross-linked, high-performance Keram special compound, VDE 0266 “HXI1”
FillerFlame retardant, halogen-free, thermoplastic compound
Inner sheathFlame retardant Polyolefin compound,CENELEC HD 604 S1 and VDE 0276-604 “HM4”
Armouring (rodent protection)Single-core cable with copper tape (CLCU) and multicore cable with galvanised steel tape (CL)
Outer sheathFlame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE 0276-604 “HM4”
Core coloursCENELEC HD 308 S2 and VDE 0293
Sheath colourOrange
Nominal voltage0.6/1kV
Test voltage4000V, 50Hz
Minimum bending radiusduring and permanent installation

15 x D (single core cable)
12 x D (multicore cable)
(D = outer diameter)

Operating temperaturepermanent installation-45°C to +90°C
 during installation-5°C to +50°C
System Circuit Integrity is dependent on installation method.

Cero halógenos, gases no corrosivos

IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA

Propagación de la flama

IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1

Dispersión de la flama

IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C, VDE 0482-332-3-22/-24 Cat. A/C, AREI-RGIE Art.104-F2

Densidad de humo

IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD

Integridad de circuito (FE180)

IEC 60331-11/-21 (180 minutes), VDE 0472 part 814 (FE180), IEC 60331-1, IEC 60331-2 (120 minutes ), EN 50200, VDE 0482-200 (PH120) and EN 50362, VDE 0482-362 (120 minutes), BS 6387 C/W/Z, AREI-RGIE Art.104-FR1

Integridad del Sistema de Circuito

DIN 4102 part 12, AREI-RGIE Art.104-FR2

Documentos

ENDENLFRCNESIT
Ficha técnica del producto
Certificado MPA

Versiones

N° de artículoProductoDiámetro [mm2]Forro Ø [mm]Peso [kg/km]Prop. Cu [kg/km]Carga de fuego [kWh/m]ConstrucciónConductor
192350(N)HXH-O CL FE180 E30-E60 2 x 1.51.514.9334.3290.94LNde corrido
187562(N)HXH-O CL FE180 E30-E60 2 x 2.52.516383.4481.02LNde corrido
191612(N)HXH-O CL FE180 E30-E60 2 x 4417450.4771.13LNde corrido
187563(N)HXH-O CL FE180 E30-E60 2 x 6618530.71151.25LNde corrido
191107(N)HXH-J CL FE180 E30-E60 3 x 1.51.516363.4431.00LNPEde corrido
186940(N)HXH-J CL FE180 E30-E60 3 x 2.52.516.3425.4721.10LNPEde corrido
192351(N)HXH-J CL FE180 E30-E60 3 x 4418508.81151.22LNPEde corrido
188326(N)HXH-J CL FE180 E30-E60 3 x 66196071731.35LNPEde corrido
191597(N)HXH-J CL FE180 E30-E60 3 x 101021785.12881.54LNPEde corrido
188327(N)HXH-J CL FE180 E30-E60 3 x 1616241074.14611.93LNPEtrenzado
190590(N)HXH-J CL FE180 E30-E60 4 x 2.52.518484.2961.223LPEde corrido
191102(N)HXH-J CL FE180 E30-E60 4 x 4419584.81541.363LPEde corrido
192593(N)HXH-J CL FE180 E30-E60 4 x 6620709.42301.513LPEde corrido
192594(N)HXH-J CL FE180 E30-E60 4 x 101022939.63841.763LPEde corrido
186980(N)HXH-J CL FE180 E30-E60 4 x 1616251292.56142.203LPEtrenzado
186981(N)HXH-J CL FE180 E30-E60 4 x 2525291813.69602.783LPEtrenzado
186982(N)HXH-J CL FE180 E30-E60 4 x 353532229613443.163LPEtrenzado
190589(N)HXH-J CL FE180 E30-E60 4 x 5050363029.319204.022LNPEtrenzado
192428(N)HXH-J CL FE180 E30-E60 4 x 7070404014.926885.053LPEtrenzado
192429(N)HXH-J CL FE180 E30-E60 4 x 9595465343.536486.523LPEtrenzado
192430(N)HXH-J CL FE180 E30-E60 4 x 120120496433.246087.263LPEtrenzado
192347(N)HXH-J CL FE180 E30-E60 5 x 1.51.518463.8721.253LNPEde corrido
188117(N)HXH-J CL FE180 E30-E60 5 x 2.52.519555.51201.383LNPEde corrido
188118(N)HXH-J CL FE180 E30-E60 5 x 4420675.21921.543LNPEde corrido
186941(N)HXH-J CL FE180 E30-E60 5 x 6621825.52881.723LNPEde corrido
186942(N)HXH-J CL FE180 E30-E60 5 x 1010241095.24801.983LNPEde corrido
187154(N)HXH-J CL FE180 E30-E60 5 x 1616271452.17682.533LNPEtrenzado
190525(N)HXH-J CL FE180 E30-E60 5 x 1616261531.17682.533LNPEtrenzado
186984(N)HXH-J CL FE180 E30-E60 5 x 2525312167.612003.233LNPEtrenzado
187132(N)HXH-J CL FE180 E30-E60 5 x 3535352701.816803.853LNPEtrenzado
190529(N)HXH-J CL FE180 E30-E60 5 x 3535352801.416803.853LNPEtrenzado
187131(N)HXH-J CL FE180 E30-E60 5 x 505039361324004.833LNPEtrenzado
191565(N)HXH-J CL FE180 E30-E60 5 x 5050393678.224004.833LNPEtrenzado
194049(N)HXH-J CL FE180 E30-E60 5 x 7070454998.933606.053LNPEtrenzado
188094(N)HXH-J CL FE180 E30-E60 6 x 4420692.62301.745LPEde corrido
185232(N)HXH-J CL FE180 E30-E60 7 x 1.51.519530.81011.386LPEde corrido
185245(N)HXH-J CL FE180 E30-E60 7 x 4421796.82691.716LPEde corrido
185247(N)HXH-J CL FE180 E30-E60 7 x 6623984.74031.96LPEde corrido
185248(N)HXH-J CL FE180 E30-E60 7 x 1010251339.86722.26LPEde corrido
188095(N)HXH-J CL FE180 E30-E60 8 x 4423834.53071.917LPEde corrido
185239(N)HXH-J CL FE180 E30-E60 12 x 2.52.523945.22882.13LPEde corrido
185233(N)HXH-J CL FE180 E30-E60 16 x 1.51.524922.92302.2415LPEde corrido
192725(N)HXH-J CL FE180 E30-E60 16 x 2.52.52611543842.5215LPEde corrido
185235(N)HXH-J CL FE180 E30-E60 30 x 1.51.5301401.34323.2529LPEde corrido
185241(N)HXH-J CL FE180 E30-E60 30 x 2.52.5331838.87203.8129LPEde corrido
Additional dimensions available on request.