FE180 & BS (norma británica)

(N)HXH FE180 E30-E60
937069Safety cable, 0.6/1kV, Keram
1614316143
937052

Safety cables are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled.
Suitable for indoor applications. For outdoor...

FE180 E30
934433Safety cable, 0.6/1kV, Keram
1614316143
934457

Safety cables are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled.
Suitable for indoor applications. For outdoor...

FE180 flex
901878Control cable flex, 300/500V, Keram
1614116141
901844

Safety cables are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled.
Suitable for indoor applications. For outdoor...

FE180 E30 CL
903224Safety cable, 0.6/1kV, armoured with rodent protection, Keram
1614216142
903172

Safety cables are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled.
Suitable for indoor applications. For outdoor...

CU 6502 4P / 2x4P F8
937261Safety cable, 0.6/1kV armoured with rodent protection, Keram
1612816128
937244

Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor...

DFS Standard 60
903053Fire alarm cable, 300/500V
1914819148
903012

Cable for fire alarm systems and emergency lighting.
For permament installation in buildings. Suitable for use in Hazardous Areas Zones 1 and 2.
Optimized for fast termination: The aluminium foil is bonded to the inside of the sheath by...

Enhanced Fire Safety Cable solid
902179Fire alarm cable, 300/500V
1914619146
902066

Cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor of +90˚C. 

DFS Enhanced 120
903031Fire alarm cable, 300/500V
1914919149
902991

Cable for fire alarm systems and emergency lighting.
For permament installation in buildings. Suitable for use in Hazardous Areas Zones 1 and 2.
Optimized for fast termination: The aluminium foil is bonded to the inside of the sheath...

FO Universal ZGGFR Safety / U-DQ(ZN)BH
902196Fire alarm cable, 300/500V, with steel wire braiding
1612616126
902162

Armoured cable for fire alarm systems and emergency lighting for permament installation in buildings.
Permitted operating temperature at conductor of +90˚C.