CU 7702 4P FRNC/GG/FRNC

Data cable, S/FTP, Category 7A, AWG22, Euroclass Cca

with rodent protection and UV resistant cable sheeth

1 Inner conductor: AWG22 Bare copper wire
2 PE insulated conductor: 1.5 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Sheath: FRNC/LSZH orange RAL 2003
6 Rodent protection: with glass rovings
7 Ripcord
8 Outer sheath: FRNC/LSZH black

Description

Applicable for outdoor installation due to rodent protection and UV resistant outer cable sheath.
Robust cable design with a high mechanical stability.
Electrically and mechanically superior quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801-1, IEC 61156-5, EN 50173-1 and EN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801-1.
Data cable for structured premise cabling with enhanced mechanical and fire protection performance.
Designed for installation in Tunnels, Metro-Systems and Buildings with augmented requirements.
With rodent protection and UV protected outer sheath. Installation in ducts, tubes and on cable support systems.
Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Supports 10Base-T, 100Base-T, 1GBase-T (1000Base-T) and 10GBase-T.
Applicable for Power over Ethernet PoE / PoE+ / 4PPoE.
Category   5e66A7CATV7A 
Frequency [MHz]141010025050060086210001200
Attenuation [dB/100m]1.73.45.316.9274042535662
NEXT [dB]1031031031031039896929085
PS NEXT [dB]1001001001001009593898782
ACR-N [dB]1011009886765854393423
PS-ACR-N [dB]98979583735551363120
ACR-F [dB]10910710593837065575446
PS-ACR-F [dB]10610410290806762545143
Return loss [dB]26303333282625242321
These performance data are typical measured values.
Loop resistance at 20˚ C:116 Ω/km
Mutual capacitance:43 pF/m
Impedance at 100 MHz:100 Ω ± 5 Ω
Transfer impedance at 1/10/30 MHz:< 5/5/8 mΩ/m
Coupling attenuation
(limit curve of critical state - IEC 61156):
> 85 dB
Near end unbalance attenuation
LCL at 1-600 MHz :
> 40 dB
Delay skew:15 ns/100m
NVP:76 %
10Base-T, 100Base-T, 1000Base-T, 2.5GBase-T, 5GBase-T, 10GBase-T
  CU 7702 4P
Bending radius
(flat side)
during draw-in:≥ 96 mm
 permanently installed:≥ 48 mm
Tensile strength: ≤ 150 N
Crush resistance: ≤ 1000 N/10 cm
Impact: ≤ 10 impacts
Temperature
range
during installation:0° C to + 50° C
 in operation:-20° C to + 60° C

Reaction to fire (Euroclasses)

EN 13501-6: Cca

Wire colour

white-blue/bluewhite-orange/orangewhite-green/greenwhite-brown/brown(with longitudinal stripes)in accordance with IEC 60189 and IEC 60708

Imprint

DATWYLER «cable type» «additional text» «batch number» «meter marks»

Zero halogen, no corrosive gases

IEC 60754-1/-2, EN 60754-1/-2

Flame propagation

IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2

Smoke density

IEC 61034-1/-2, EN 61034-1/-2

PoE

IEEE 802.3at

EMC

shielded

Segregation class

d

Cat./Class

Cat 7A / Class FA - limit values as specified by IEC 61156-5 and EN 50288-9-1 guaranteed

Documentation

ENDENLFRCNESIT
Product Datasheet
GHMT PVP Certificates

Versions

Article No.DoPProductReaction to fire (Euroclasses)Dimensions n x p x [mm (AWG)]SheathSheath colourSheath Ø [mm]Weight [kg/km]Cu rate [kg/km]Fire load [MJ/m]Fire load [kWh/m]PU
19435400CZCU 7702 4PCca-s1a,d1,a14 x 2 x 0.62 (AWG22)FRNC/LS0Hblack12.016734.91.98 MJ/m0.55by the metre

Related products

CU 8203 4P

Data cable, S/FTP, Category 8.2, AWG23, Euroclass Dca

CU 8203 4P

Data cable, S/FTP, Category 8.2, AWG23, Euroclass Cca

CU 8203 4P

Data cable, S/FTP, Category 8.2, AWG23, Euroclass B2ca