CU 7702 4P / 2x4P F8

Data cable, S/FTP, Category 7A, AWG22, Euroclass Dca

1 Inner conductor: AWG22 Bare copper wire
2 PE insulated conductor: 1.5 mm ∅
3 Screen (pair): Alu PETP foil  
4 Overall screen: Tinned braided copper 
5 Outer sheath: FRNC/LSOH orange RAL 2003

Description

Electrically and mechanically superior quality Cat.7A data cable - exceeds the requirements of ISO/IEC 11801, IEC 61156-5, IEC 61156-7, EN 50173-1 and prEN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Easy identification of wires thanks to longitudinal colour markings.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with IEC 15018.
Due to the increased wire section eminently suited for Power over Ethernet (PoE) / PoE+ and 4PPoE.
Category   5e66A7CATV7A 
Frequency [MHz]141010025050060086210001200
Attenuation [dB/100m]1.73.45.316.9274042535662
NEXT [dB]1031031031031039896929085
PS NEXT [dB]1001001001001009593898782
ACR-N [dB]1011009886765854393423
PS-ACR-N [dB]98979583735551363120
ACR-F [dB]10910710593837065575446
PS-ACR-F [dB]10610410290806762545143
Return loss [dB]26303333282625242321
These performance data are typical measured values.
Category:Cat.7A
Coupling attenuation:85 dB
Delay Skew:15 ns/100 m
Impedance at 100 MHz, ±5Ω:100 Ω
Loop resistance at 20°C:< 116 Ω/km
Near end unbalance attenuation LCL at 1-600 MHz:40 dB
NVP %:76
operating capacity:43 pF/m
Transfer impedance 1/10/30 MHz:< 5/5/8 mΩ/m
Minimum bending radius during installation:64 mm
Minimum bending radius permanently installed:32 mm
Tensile strength (4P):120 N
Tensile strength (2x4P):240 N
Minimal crush resistance / 10cm:1,000 N
Minimum number of impacts:10
Installation temperature:0 °C - +50 °C
Operating temperature:-20 °C - +60 °C

Reaction to fire (Euroclasses)

EN 13501-6: Dca

Wire colour

white-blue/bluewhite-orange/orangewhite-green/greenwhite-brown/brown(with longitudinal stripes)in accordance with IEC 60189 and IEC 60708

Imprint

DATWYLER «cable type» «additional text» «batch number» «meter marks»

Zero halogen, no corrosive gases

IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA

Flame propagation

IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1

Flame spread

IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2

Smoke density

IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD

PoE

IEEE 802.3at

EMC

shielded

Segregation class

d

Cat./Class

Cat 7A / Class FA - limit values as specified by IEC 61156-5 and EN 50288-9-1 guaranteed

Documentation

ENDENLFRCNESIT
Product Datasheet
Tender text
GHMT PVP Certificates
GHMT PM/Channel Certificates
Transmission Parameter

Versions

Article No.DoPProductReaction to fire (Euroclasses)Dimensions n x p x [mm (AWG)]SheathSheath colourSheath Ø [mm]Weight [kg/km]Cu rate [kg/km]Fire load [MJ/m]Fire load [kWh/m]PU
17740000DKCU 7702 4PDca-s2,d1,a14 x 2 x 0.62 (AWG22)FRNC/LS0Horange7.66234.90.64 MJ/m0.181000 m drum
17740000DLCU 7702 4PDca-s2,d1,a14 x 2 x 0.62 (AWG22)FRNC/LS0Horange7.66234.90.64 MJ/m0.18500 m drum
17739000DLCU 7702 2x4PDca-s2,d1,a12 x (4 x 2 x 0.62 (AWG22))FRNC/LS0Horange12569.81.29 MJ/m0.36500 m drum