CU 7120 4P / 2x4P F8

Data cable, S/FTP, Category 7A, AWG 23, Euroklasse Cca

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.5 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Tinned braided copper
5 Outer sheath: FRNC/LSOH Orange RAL 2003

Description

Electrically and mechanically advanced quality Cat.7A data cable - fulfils the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-9-1.
Excellent shielding effect due to individually screened pairs and overall copper braid.
Reduced outer diameter.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class FA applications (1000 MHz) in accordance with EN 50173-1 and ISO/IEC 11801 and for the transmission of broadband signals (such as cable TV) in accordance with ISO/IEC 11801-4.
Applicable for Power over Ethernet PoE / PoE+ / 4PPoE up to 100W.
Category   5e66A7CATV7A 
Frequency [MHz]141010025050060086210001300
Attenuation [dB/100m]1.83.55.417.7284146545764
NEXT [dB]1031031031031039896929085
PS NEXT [dB]1001001001001009593898782
ACR-N [dB]1011009885755750383321
PS-ACR-N [dB]98979582725447353018
ACR-F [dB]10810610492826964565346
PS-ACR-F [dB]10510310189796661535043
Return loss [dB]26303333282625242320
These performance data are typical measured values.
Category:Cat.7A
Coupling attenuation:85 dB
Delay Skew:14 ns/100 m
Impedance at 100 MHz, ±5Ω:100 Ω
Loop resistance at 20°C:< 134 Ω/km
Near end unbalance attenuation LCL at 1-600 MHz:40 dB
NVP %:76
operating capacity:44 pF/m
Transfer impedance 1/10/30 MHz:< 5/5/8 mΩ/m
10Base-T, 100Base-T, 1000Base-T, 2.5GBase-T, 5GBase-T, 10GBase-T
Minimum bending radius during installation:60 mm
Minimum bending radius permanently installed:30 mm
Tensile strength (4P):110 N
Tensile strength (2x4P):220 N
Minimal crush resistance / 10cm:1,000 N
Minimum number of impacts:10
Installation temperature:0 °C - +50 °C
Operating temperature:-20 °C - +60 °C

Reaction to fire (Euroclass)

EN 13501-6: Cca

Wire colour

white/bluewhite/orangewhite/greenwhite/brownin accordance with IEC 60189 and IEC 60708

Imprint

DATWYLER «cable type» «additional text» «batch number» «meter marks»

Zero halogen, no corrosive gases

IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA

Flame propagation

IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1

Flame spread

IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2

Smoke density

IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD

PoE

IEEE 802.3bt

EMC

shielded

Segregation class

d

Cat./Class

Cat 7A / Class FA - limit values as specified by IEC 61156-5 and EN 50288-9-1 guaranteed

Documentation

ENDENLFRCNESIT
Product Datasheet
GHMT PVP Certificates
Transmission Parameter

Versions

Article No.DoPProductReaction to fire (Euroclass)Dimensions n x p x [mm (AWG)]SheathSheath colourSheath Ø [mm]Weight [kg/km]Cu rate [kg/km]Fire load [MJ/m]Fire load [kWh/m]PU
19146702CLCU 7120 2x4PCca-s1b,d1,a12 x (4 x 2 x 0.59 (AWG23))FRNC/LS0Horange7.6 x 16.012164.61.298 MJ/m0.36500 m drum
19146600CLCU 7120 4PCca-s1a,d1,a14 x 2 x 0.59 (AWG23)FRNC/LS0Horange7.66032.30.649 MJ/m0.18500 m drum

Related products

CU 8203 4P

Data cable, S/FTP, Category 8.2, AWG23, Euroclass Dca

CU 8203 4P

Data cable, S/FTP, Category 8.2, AWG23, Euroclass Cca

CU 8203 4P

Data cable, S/FTP, Category 8.2, AWG23, Euroclass B2ca