J-H(St)H...Bd

Wiring cable for telecomunication systems, max. 300V, Euroclass Dca

halogen-free, with improved fire characteristics,
VDE 0815

1 Conductor: solid
2 Insulation: halogen-free polymer compound wire 
3 Drain wire: tinned copper 
4 Separator: plastic tape
5 Shielding: Alu-laminated plastic foil
6 Sheaths: FRNC/LSZH

Description

Installation cable with electrostatic shield for areas vulnerable to fire and with high concentration of people and property value. For ICT systems for lossless data and signal transmission. Suitable for laying in dry and humid rooms, on-wall and in-wall, also for outdoor use.
No underground laying. Not to be used for high-voltage transmission.
Permitted operating temperature at conductor of +70° C.
Conductor:Bare copper, solid, 0.6 or 0.8 mm diameter
Insulation:Halogen-free polymer compound, EN 50290-2-26
Core idendification:DIN VDE 0815 (different colours)
Stranding:Cores twisted to star-quads and quads to units
Shielding:Al-laminated plastic foil with drain wire, copper tinned
Outer sheath:Halogen-free polymer compound, EN 50290-2-27
Sheath colour:Grey
Rated voltage:max. 300V
Test voltage:800V 50Hz
Conductor resistance Loop:

0.6 mm max. 130 Ω/km

 

0.8 mm max. 73,2 Ω/km

Insulation resistance:

min. 100 MΩ x km

Capacity:max. 120 nF/km
Minimum bending radiuspermanent installation:2.5 x D
 during installation:7.5 x D (D = outer diameter)
Operating temperaturepermanent installation:-30 °C bis +70 °C
 during installation:- 5 °C bis +50 °C
Additional dimensions available on request.

Reaction to fire (Euroclass)

EN 13501-6: Dca

Zero halogen, no corrosive gases

IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA

Flame propagation

IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1

Flame spread

IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2

Smoke density

IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD

Documentation

ENDENLFRCNESIT
Product Datasheet
Tender text

Versions

Article No.ProductNumber of PairsNumber of CoresDiameter [mm]Sheath colourSheath Ø [mm]Weight [kg/km]Cu rate [kg/km]Fire load [kWh/m]PU
15283301DZJ-H(St)H...Bd 2x2x0.6 mm220.6grey5.442140.10by the metre
15283401DZJ-H(St)H...Bd 4x2x0.6 mm420.6grey7.169250.15by the metre
15283501DZJ-H(St)H...Bd 6x2x0.6 mm620.6grey8.486370.18by the metre
15283601DZJ-H(St)H...Bd 10x2x0.6 mm1020.6grey9.9124590.23by the metre
15283701DZJ-H(St)H...Bd 20x2x0.6 mm2020.6grey15.52371160.39by the metre
15445001DZJ-H(St)H...Bd 30x2x0.6 mm3020.6grey16.33241720.55by the metre
15445101DZJ-H(St)H...Bd 40x2x0.6 mm4020.6grey15.74102290.67by the metre
15445201DZJ-H(St)H...Bd 50x2x0.6 mm5020.6grey20.75152860.79by the metre
15445301DZJ-H(St)H...Bd 60x2x0.6 mm6020.6grey22.66003420.96by the metre
15445401DZJ-H(St)H...Bd 80x2x0.6 mm8020.6grey24.88004551.38by the metre
15445501DZJ-H(St)H...Bd 100x2x0.6 mm10020.6grey28.29905681.56by the metre
19100101DZJ-H(St)H...Bd 1x2x0.8 mm120.8grey5.756150.11by the metre
15283801DZJ-H(St)H...Bd 2x2x0.8 mm220.8grey6.569250.13by the metre
15268901DZJ-H(St)H...Bd 4x2x0.8 mm420.8grey10112450.20by the metre
15283901DZJ-H(St)H...Bd 6x2x0.8 mm620.8grey10.5141650.35by the metre
15284001DZJ-H(St)H...Bd 10x2x0.8 mm1020.8grey132041060.32by the metre
15284101DZJ-H(St)H...Bd 20x2x0.8 mm2020.8grey20.43702060.61by the metre
11599671DZJ-H(St)H...Bd 30x2x0.8 mm3020.8grey17.35243070.78by the metre
11720121DZJ-H(St)H...Bd 40x2x0.8 mm4020.8grey19.46664071.02by the metre
11720131DZJ-H(St)H...Bd 50x2x0.8 mm5020.8grey21.38105081.20by the metre
11720141DZJ-H(St)H...Bd 60x2x0.8 mm6020.8grey22.69756081.37by the metre
11720151DZJ-H(St)H...Bd 80x2x0.8 mm8020.8grey30.813258092.06by the metre
11720161DZJ-H(St)H...Bd 100x2x0.8 mm10020.8grey31.9160010102.35by the metre
DoP available on request

Related products

NHXMH

Power cable, 300/500V

(N)HXM(St)H

Shielded power cable, 300/500V

N2XH

Safety cable, single-core, 0.6/1kV, Euroclass Cca