E0 / FE5

NHXMH
901149Power cable, 300/500V
1616516165
901106

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete, except for direct embedding in cast, rammed or vibrated concrete.
Also suitable for outdoor applications.

(N)HXM(St)H
901178Shielded power cable, 300/500V
1616416164
901213

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete, except for direct embedding in cast, rammed or vibrated concrete.
Also suitable for outdoor applications.
Permitted operating...

N2XH_
901520Safety cable, single-core, 0.6/1kV, Euroclass Cca
1617016170
901477

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used.
...

N2XH.
901625Safety cable, multicore, 0.6/1kV, Euroclass Cca
1616916169
901581

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used.
...

N2XH
901285Safety cable, 0.6/1kV
1616816168
901242

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications. The cable should only be laid directly in earth or water if a protective conduit is used.
...

N2XCH.
901645Safety cable, 0.6/1kV, Euroclass Cca
1917519175
901602

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications.
The cable should only be laid directly in earth or water if a protective conduit is used.
...

N2XCH
901468Safety cable, 0.6/1kV
1917519175
901424

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications.
The cable should only be laid directly in earth or water if a protective conduit is used.
...

J-H(St)H...Bd
901672Wiring cable for telecomunication systems, max. 300V, Euroclass Dca
1321713217
901640

Installation cable with electrostatic shield for areas vulnerable to fire and with high concentration of people and property value. For ICT systems for lossless data and signal transmission. Suitable for laying in dry and humid rooms,...

J-H(St)H...Bd fire alarm .
901767Fire alarm cable, max. 300V
1616016160
901732

Installation cable with electrostatic shield for areas vulnerable to fire and with high concentration of people and property value. For ICT systems for lossless data and signal transmission. Suitable for laying in dry and humid rooms,...

FE5-CL
901496Safety cable, 0.6/1kV, armoured with rodent protection
1614416144
901453

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications.
The cable should only be laid directly in earth or water if a protective conduit is used.
...