FM – Low Fire Hazard – supported

Drawing according to article number 185124 - Type 8696-F

Description

Elevator suspension cable for indoor and panoramic elevators.
To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
Core flexible:class 5
Core insulation:low fire hazard
Data elements:

Please find our detailed interactive product overview here.

Supporting members:HTF = High tensile fibre
Outer sheath:low fire hazard
Rated voltage Uo/U:according to table
Free suspension length:maximum 80 m
Travelling height:maximum 150 m
Running speed:maximum 6.3 m/s
Acceleration:< 1.2 m/s2
Operating temperature:-15 to +70 °C
Recommended loop diameter:according to table, tolerance -50/+100 mm
Core:black, white numbered,
G = with green-yellow core(s)
Pair/quad:various colours or black with white numbers
Coax:black

Sheath colour

black

Standards

EN 50214

Documentation

ENDENLFRCNESIT
Product Datasheet

Versions

Article No.ProductCu rate [kg/km]Rated voltage [V]Suspension deviceLoop [mm]StandardsSupporting membersCross sectional area [n x mm²]Weight [kg/100m]Data elementsOverall dimensions [mm x mm]
1851278622-F139

300/500

 

LZ 1006400EN 50214HTF

12 G 1.00

+ 1 x CX 75 Ω

48.4

 

HF-2123-F

48.4 x 6.0
1851248696-F142

300/500

300/300

LZ 1006400EN 50214HTF

12 G 1.00

+ 1 x 4 x 0.34

49.9

8607-F

48.4 x 6.0
1910948872-F232

450/750

300/500

300/300

LZ 1009400EN 50214HTF

3 G 2.50

+ 14 x 1.00

+ 4 x 2 x 0.50

81.8

 

 

6651-F

 

79.0 x 5.7