Dome closures FDN59-IR

Integrated Routing (IR)

Fiber-optic splice closure FDN59-IR

产品描述

The FDN59-IR is a medium to large oval shaped dome closure offering a high number of small cable engties (ports) for use in underground, direct burial or aerial installations, available with Integrated Routing (IR) or tubing fibre management systems.
The base configuration of this FDN has 56 round ports and 1 oval port for loop through applications. The oval port can also be used as a round port offering 2 additional ports.  
The closure cover, which can be fitted with a pressure valve, is available in 4 different lengths depending on the maximum number of trays required. It is environmentally sealed to the base using an ‘O’ ring and quick release clamp. The cables are sealed using either mechanical seals (CablelokTM) or heathshrink sleeves (except the R ports).
The mounting backplane can accommodate up to 36 IR SE trays or 72 IR SC trays or a combination of both. Its position allows easy access to the trays. The basket provides space for the storage of fibre loops. The trays and fibre optic routing module are white which makes it easy to see the colour of the fibre elements as they are routed.
The foam pad on the retainer is partially cut trough to accommodate a range of fibre counts.
All IR system cover plates are coloured blue identifying them as removable parts allowing access to the fibre. The fibre slot retaining block and tray retaining clips are coloured red.

Base configuration:
PortNumber of portsCable diameter range - CablelokCable diameter range - heatshrink
L12 x 5.5 – 20.0 mm2 x 10.0 – 24.0 mm
T215.5 – 29.0 mm8.0 – 35.0 mm
S45.0 – 20.0 mm12.0 – 26.0 mm
B24.8 – 16.5 mm6.0 – 19.0 mm
R521.7 – 9.5 mm-

The high number of drop ports means that this closure is particularly suited for use in FTTx access networks.
The oval shape ensures that the FDN can be used where space is limited.

Datwyler provide the closures ready to use, with fibre management and splice trays in standard configurations.
If a standard configuration is not suitable, the closures can be supplied without splice trays which can then be ordered separately.
Cable entry seals (Cablelok and heatshrink) and accessories such as mounting brackets must be ordered separately.
 
FDN IR baseStorage unit lidMarker kit
A, AB, B or C cover (dome)Fibre entry moduleredC/B1-48AB1-25A1-12
Quick release clampFibre retaining blockgreenC/B1-48AB1-25A1-12
Sealing ’O’ ringCable tieswhiteC/B1-33AB1-33A1-33
Storage [Loop] basket

Tray lid

Isopropyl alcohol
wipes   
Fibre storage unitTray mountingDesiccant   
Fibre routing moduleAnchor fixing kitsInstallation guide   
 Spiral binding 

 

Dimensions and capacities: 
CoverWidth
LengthSingle Element (SE) splice tray Single Circuit (SC) splice tray 
Size(mm x mm)(mm)singlemax. splicessinglemax. splices
A312 x 2224556(1)*7212(1)48
AB312 x 22256112(12)*14424(2)96
B312 x 22266324(4)28848(4)192
C312 x 22278936(6)43272(6)288
*single splice trays (multipacks)
Cable enttries (ports):

58 round ports or
56 round ports and 1 oval  (loop) port
52x R, 2x B, 4x S, 2x T, 1x L

Cable diameter:1.7 – 29.0 mm with Cablelok
6.0 – 35.0 mm with heatshrink
Up to 110 cables / microducts
Splice trays:

Up to 36 IR SE splice trays à 24 splices (ANT)
Up to 72 IR SC splice trays à 4 splices (ANT)
Up to 72 IR SC-B splice trays à 12 splices (ANT)
Or a combination of SE, SE-B, SC and SC-B splice trays
Splitter accommodation 70 x 20 x 6 mm

Fibres:The splice capacity depends on the splice protector type
ANT: up to 864 fibres
3A: up to 432 fibres (864 fibres double stacked)
6A: up to 648 fibres
SC (ANT/3A): up to 288 fibres
SC-B (ANT/3A): up to 864 fibres
Loop storage basket:Optional
Dimensions:A:   312 x 222 x 455 mm
AB: 312 x 222 x 561 mm
B:   312 x 222 x 663 mm
C:   312 x 222 x 789 mm
Closing:Quick release clamp, sealable / lockable 
Water head:8 m
Option:Space for internal gasblocker termination, protected from dirt, inside the closure
(longer IR arm required)
Features:Ideal for FTTH network applications, especially for the last mile/kilometre
Suitable for blown fibre applications
Cablelok compatible for all port sizes
High flexibility:Modular concept, future-proof on existing and future networks

 

Individual, project-specific pre-configured assemblies are available on request.

文献

ENDENLFRCNESIT
Product Datasheet

订购信息

产品型号产品Number of fibresDome length [mm]Splice typeTray typeQtyCable entry sealBasket
345003FDNIR-CXBCXXC 789CablelokTM,
Heatshrink
with
345551FDNIR-CXBCSX864C 789ANTIR SE36CablelokTM,
Heatshrink
with
345552FDNIR-CXBCWX432C 7893AIR SE36CablelokTM,
Heatshrink
with
345553FDNIR-CXBCYX648C 7896AIR SE36CablelokTM,
Heatshrink
with
345555FDNIR-CXBCXW288C 7896AIR SE72CablelokTM,
Heatshrink
with
345556FDNIR-CXBCXN864C 7893AIR SC-B72CablelokTM,
Heatshrink
with
345554FDNIR-CXBCXS864C 789ANTIR SC-B72CablelokTM,
Heatshrink
with
345570FDNIR-CXXCXXC 789CablelokTM,
Heatshrink
without
345571FDNIR-CXXCSX864C 789ANTIR SE36CablelokTM,
Heatshrink
without
345572FDNIR-CXXCWX432C 7893AIR SE36CablelokTM,
Heatshrink
without
345573FDNIR-CXXCYX648C 7896AIR SE36CablelokTM,
Heatshrink
without
345575FDNIR-CXXCXW288C 789ANT/3AIR SC72CablelokTM,
Heatshrink
without
345576FDNIR-CXXCXN864C 7893AIR SC-B72CablelokTM,
Heatshrink
without
345574FDNIR-CXXCXS864C 789ANTIR SC-B72CablelokTM,
Heatshrink
without
345560FDNIR-CXBCXX
-SPECIAL
C 789CablelokTM,
Heatshrink
with
345561FDNIR-CXBCSX
-SPECIAL
720C 789ANTIR SE30CablelokTM,
Heatshrink
with
345562FDNIR-CXBCWX
-SPECIAL
360C 7893AIR SE30CablelokTM,
Heatshrink
with
345563FDNIR-CXBCYX
-SPECIAL
540C 7896AIR SE30CablelokTM,
Heatshrink
with
345565FDNIR-CXBCXW
-SPECIAL
240C 789ANT/3AIR SC60CablelokTM,
Heatshrink
with
345566FDNIR-CXBCXN
-SPECIAL
720C 7893AIR SC-B60CablelokTM,
Heatshrink
with
345564FDNIR-CXBCXS
-SPECIAL
720C 789ANTIR SC-B60CablelokTM,
Heatshrink
with
345580FDNIR-CXXCXX
-SPECIAL
C 789CablelokTM,
Heatshrink
without
345581FDNIR-CXXCSX
-SPECIAL
720C 789ANTIR SE30CablelokTM,
Heatshrink
without
345582FDNIR-CXXCWX
-SPECIAL
360C 7893AIR SE30CablelokTM,
Heatshrink
without
345583FDNIR-CXXCYX
-SPECIAL
540C 7896AIR SE30CablelokTM,
Heatshrink
without
345585FDNIR-CXXCXW
-SPECIAL
240C 789ANT/3AIR SC60CablelokTM,
Heatshrink
without
345586FDNIR-CXXCXN
-SPECIAL
720C 7893AIR SC-B60CablelokTM,
Heatshrink
without
345584FDNIR-CXXCXS
-SPECIAL
720C 789ANTIR SC-B60CablelokTM,
Heatshrink
without
345002FDNIR-BXBCXXB 663CablelokTM,
Heatshrink
with
345591FDNIR-BXBCSX576B 663ANTIR SE24with
345592FDNIR-BXBCWX288B 6633AIR SE24CablelokTM,
Heatshrink
with
345593FDNIR-BXBCYX432B 663ANT/3AIR SE24CablelokTM,
Heatshrink
with
345595FDNIR-BXBCXW192B 663ANT/3AIR SC48CablelokTM,
Heatshrink
with
345596FDNIR-BXBCXN576B 6633AIR SC-B48CablelokTM,
Heatshrink
with
345594FDNIR-BXBCXS576B 663ANTIR SC-B48CablelokTM,
Heatshrink
with
345610FDNIR-BXXCXXB 663CablelokTM,
Heatshrink
without
345611FDNIR-BXXCSX576B 663ANTIR SE24CablelokTM,
Heatshrink
without
345612FDNIR-BXXCWX288B 6633AIR SE24CablelokTM,
Heatshrink
without
345613FDNIR-BXXCYX24B 6636AIR SE24CablelokTM,
Heatshrink
without
345615FDNIR-BXXCXW192B 663ANT/3AIR SC48CablelokTM,
Heatshrink
without
345616FDNIR-BXXCXN576B 6633AIR SC-B48CablelokTM,
Heatshrink
without
345614FDNIR-BXXCXS576B 663ANTIR SC-B48CablelokTM,
Heatshrink
without
345600FDNIR-BXBCXX
-SPECIAL
B 663CablelokTM,
Heatshrink
with
345601FDNIR-BXBCSX
-SPECIAL
432B 663ANTIR SE18CablelokTM,
Heatshrink
with
345602FDNIR-BXBCWX
-SPECIAL
216B 663ANTIR SE18CablelokTM,
Heatshrink
with
345603FDNIR-BXBCYX
-SPECIAL
324B 6636AIR SE18CablelokTM,
Heatshrink
with
345605FDNIR-BXBCXW
-SPECIAL
144B 663ANT/3AIR SC36CablelokTM,
Heatshrink
with
345606FDNIR-BXBCXN
-SPECIAL
432B 6633AIR SC-B36CablelokTM,
Heatshrink
with
345604FDNIR-BXBCXS
-SPECIAL
432B 663ANTIR SC-B36CablelokTM,
Heatshrink
with
345620FDNIR-BXXCXX
-SPECIAL
B 663CablelokTM,
Heatshrink
345621FDNIR-BXXCSX
-SPECIAL
432B 663ANTIR SE18CablelokTM,
Heatshrink
without
345622FDNIR-BXXCWX
-SPECIAL
216B 6633AIR SE18CablelokTM,
Heatshrink
without
345623FDNIR-BXXCYX
-SPECIAL
324B 6636AIR SE18CablelokTM,
Heatshrink
without
345625FDNIR-BXXCXW
-SPECIAL
144B 663ANT/3AIR SC36CablelokTM,
Heatshrink
without
345626FDNIR-BXXCXN
-SPECIAL
432B 6633AIR SC-B36CablelokTM,
Heatshrink
without
345624FDNIR-BXXCXS
-SPECIAL
432B 663ANTIR SC-B36CablelokTM,
Heatshrink
without
345001FDNIR-ABBCXXAB 561CablelokTM,
Heatshrink
with
345631FDNIR-ABBCSX288AB 561ANTIR SE12CablelokTM,
Heatshrink
with
345632FDNIR-ABBCWX144AB 5613AIR SE12CablelokTM,
Heatshrink
with
345633FDNIR-ABBCYX216AB 5616AIR SE12CablelokTM,
Heatshrink
with
345635FDNIR-ABBCXW96AB 561ANT/3AIR SC24CablelokTM,
Heatshrink
with
345636FDNIR-ABBCXN288AB 5613AIR SC-B24CablelokTM,
Heatshrink
with
345634FDNIR-ABBCXS288AB 561ANTIR SC-B24CablelokTM,
Heatshrink
with
345650FDNIR-ABXCXXAB 561CablelokTM,
Heatshrink
without
345651FDNIR-ABXCSX288AB 561IR SE12CablelokTM,
Heatshrink
without
345652FDNIR-ABXCWX144AB 5613AIR SE12CablelokTM,
Heatshrink
without
345653FDNIR-ABXCYX216AB 5616AIR SE12CablelokTM,
Heatshrink
without
345655FDNIR-ABXCXW96AB 561ANT/3AIR SC24CablelokTM,
Heatshrink
without
345656FDNIR-ABXCXN288AB 5613AIR SC-B24CablelokTM,
Heatshrink
without
345654FDNIR-ABXCXS192AB 561ANTIR SC-B24CablelokTM,
Heatshrink
without
345640FDNIR-ABBCXX
-SPECIAL
AB 561CablelokTM,
Heatshrink
with
345641FDNIR-ABBCSX
-SPECIAL
144AB 561ANTIR SE6CablelokTM,
Heatshrink
with
345642FDNIR-ABBCWX
-SPECIAL
72AB 5613AIR SE6CablelokTM,
Heatshrink
with
345643FDNIR-ABBCYX
-SPECIAL
108AB 5616AIR SE6CablelokTM,
Heatshrink
with
345645FDNIR-ABBCXW
-SPECIAL
48AB 561ANT/3AIR SC12CablelokTM,
Heatshrink
with
345646FDNIR-ABBCXN
-SPECIAL
144AB 5613AIR SC-B12CablelokTM,
Heatshrink
with
345644FDNIR-ABBCXS
-SPECIAL
144AB 561ANTIR SC-B12CablelokTM,
Heatshrink
with
345660FDNIR-ABXCXX
-SPECIAL
AB 561CablelokTM,
Heatshrink
without
345661FDNIR-ABXCSX
-SPECIAL
144AB 561ANTIR SE6CablelokTM,
Heatshrink
without
345662FDNIR-ABXCWX
-SPECIAL(3A)
72AB 5613AIR SE6CablelokTM,
Heatshrink
without
345663FDNIR-ABXCYX-
-SPECIAL(6A)
108AB 5616AIR SE6CablelokTM,
Heatshrink
without
345665FDNIR-ABXCXW-
-SPECIAL (SC)
48AB 561ANT/3AIR SC12CablelokTM,
Heatshrink
without
345666FDNIR-ABXCXN-
-SPECIAL (SC-B)
144AB 5613AIR SC-B12CablelokTM,
Heatshrink
without
345664FDNIR-ABXCXS-
-SPECIAL (SC-B)
144AB 561ANTIR SC-B12CablelokTM,
Heatshrink
without
345000FDNIR-AXBCXXA 455CablelokTM,
Heatshrink
with
345671FDNIR-AXBCSX144A 455ANTIR SE6CablelokTM,
Heatshrink
with
345672FDNIR-AXBCWX72A 4553AIR SE6CablelokTM,
Heatshrink
with
345673FDNIR-AXBCYX108A 4556AIR SE6CablelokTM,
Heatshrink
with
345675FDNIR-AXBCXW48A 4553AIR SC12CablelokTM,
Heatshrink
with
345676FDNIR-AXBCXN144A 4553AIR SC-B12CablelokTM,
Heatshrink
with
345674FDNIR-AXBCXS144A 455ANTIR SC-B12CablelokTM,
Heatshrink
with
345680FDNIR-AXXCXXA 455CablelokTM,
Heatshrink
without
345681FDNIR-AXXCSX144A 455ANTIR SE6CablelokTM,
Heatshrink
without
345682FDNIR-AXXCWX72A 4553AIR SE6CablelokTM,
Heatshrink
without
345683FDNIR-AXXCYX108A 4556AIR SE6CablelokTM,
Heatshrink
without
345685FDNIR-AXXCXW48A 455ANT/3AIR SC12CablelokTM,
Heatshrink
without
345686FDNIR-AXXCXN144A 4553AIR SC-B12CablelokTM,
Heatshrink
without
345684FDNIR-AXXCXS96A 455ANTIR SC-B12CablelokTM,
Heatshrink
without

相关产品

Dome closures UFC-IR

Integrated Routing (IR)

Dome closures FDN16-IR

Integrated Routing (IR)